HARDWARE INFRASTRUCTURE

SRP-100W
Smart Edge Gateway

Integrate RS232, RS485, and TCP/IP communications into just one device. SRP-100W is the most powerful edge gateway that collects various facility data and transmits it to Resource Lake.

Key features

Real-time

Real-time data processing

Multi-Core

Multi-protocol support

Rugged

industrial durability

SRP-100W
SMART REPEATER
VENTILATION

Technical Specifications

Rugged design to withstand harsh industrial environments

A signal wire is landed on the terminal block of a DIN-rail edge gateway inside a machine-side control cabinet
Signal tap-offThis is usually where the gateway goes — taking the signal straight from an older machine’s terminal box.
Model NameSRP-100W (Smart Repeater)
CommunicationRS232, RS485, TCP/IP, Wi-Fi
Protocol SupportModbus RTU/TCP, MQTT, Custom
Input PowerDC 12V ~ 24V (Industrial Grade)

Quick Answers

Key questions about the SRP-100W edge gateway

Connections and responsibilities for shop-floor equipment data collection.

What is the SRP-100W?

It is an industrial edge gateway that collects signals near manufacturing equipment and reliably transfers them to a data platform or MES.

Which connections are supported?

It supports RS232, RS485, and TCP/IP connections. The final protocols and data points are defined after inspecting the target equipment.

Does existing equipment need replacement?

The gateway uses available ports and signals on existing equipment, so integration is designed around the smallest practical change after assessment.

Sources and standards

Terms and procedures on this page follow the public standards and official sources below. Figures are as of each source's publication date.

Key facts
TopicSRP-100W Industrial Edge Gateway | IYULAB
SectionHardware
Standards appliedModbus protocol specifications (Modbus Organization) · RS-485 Design Guide (Texas Instruments, SLLA070) · OPC UA (OPC Foundation)
Public recordGS certification grade 1 of 2 grades · 7 patents registered
Reviewed byIYULAB engineering team
Last updated
  • Modbus protocol specifications (Modbus Organization)The Modbus RTU, ASCII and TCP specifications. RTU uses slave addresses 1 to 247; TCP uses port 502.Key figures: up to 247 slave devices per line, introduced 1979
  • RS-485 Design Guide (Texas Instruments, SLLA070)Summarises the TIA/EIA-485 electrical limits: 32 unit loads and roughly 1,200 m of cable as the design baseline.Key figures: up to 32 unit loads, up to 10 Mbps
  • OPC UA (OPC Foundation)The equipment data exchange standard published as IEC 62541; default port 4840, with an information model and a security layer.Key figures: IEC 62541, version 1.0 released 2008

Public record: GS certification, grade 1 of 2 grades (U-CMMS 3.0, Telecommunications Technology Association) · 7 patents registered (10-2141840, 10-2141847, 10-2147747, 10-2354546, 10-2408497, 10-2408501, 10-2698341; searchable by number on KIPRIS) · Certifications and patentsReviewed by the IYULAB engineering team · Last updated: