SCADA

SCADA monitors — and where needed controls — many machines from a single screen. Its job is to show you what is happening right now.

How it connects

  1. Equipment · PLC

    Field states and measurements

  2. Acquisition · Supervision

    Live screens, alarms and history

  3. Operator

    Review conditions and control decisions

Definition

Definition

SCADA monitors — and where needed controls — many machines from a single screen. Its job is to show you what is happening right now.

In more detail

SCADA reads values from controllers such as PLCs, displays them, raises alarms, and lets an operator change setpoints. It matured first in continuous industries like power, water and chemicals, and is now common in discrete manufacturing too.

SCADA is concerned with current state: what temperature, which machine stopped. MES is concerned with how this work order was executed — a history. They look at different things.

In many plants SCADA already exists but its data stays inside it. You can watch it on screen, yet it is never grouped by lot or joined to inspection results, so it never reaches root-cause analysis.

How it is used on the floor

  • Monitor equipment state and alarms from one screen.
  • Change setpoints and run operations from the control room.
  • Lift values SCADA already collects into MES and analytics instead of collecting them twice.

If we have SCADA, do we need MES?

They serve different axes. SCADA organises data by equipment; MES organises it by order and lot. "What temperature is machine 3 right now" is a SCADA question. "What conditions produced this lot and who worked on it" is an MES question. In practice MES often consumes SCADA data and attaches it to the lot.

Related terms

Terms that make more sense read together.

Related products

What IYULAB provides in this area.

Quick Answers

SCADA — frequently asked

Questions that come up when evaluating SCADA.

Can SCADA data be pulled into MES?

Usually yes. If SCADA exposes a database or an OPC interface, read from there; if not, reading the PLC directly is the alternative.

Is SCADA the same as HMI?

An HMI is typically the operator panel attached to one machine. SCADA supervises many machines as a higher-level system. Think of it as a difference of scale and scope.

Do we need SCADA before we can collect data?

No. If collection is the only goal, reading PLCs through an edge gateway is simpler and cheaper.